This website is intended for healthcare professionals

Abstract

Assessment of body temperature is important for decisions in nursing care, medical diagnosis, treatment and the need of laboratory tests. The definition of normal body temperature as 37°C was established in the middle of the 19th century. Since then the technical design and the accuracy of thermometers has been much improved. Knowledge of physical influence on the individual body temperature, such as thermoregulation and hormones, are still not taken into consideration in body temperature assessment. It is time for a change; the unadjusted mode should be used, without adjusting to another site and the same site of measurement should be used as far as possible. Peripheral sites, such as the axillary and the forehead site, are not recommended as an assessment of core body temperature in adults. Frail elderly individuals might have a low normal body temperature and therefore be at risk of being assessed as non-febrile. As the ear site is close to the hypothalamus and quickly responds to changes in the set point temperature, it is a preferable and recommendable site for measurement of body temperature.

References

  • Augustine SD (1990) Hypothermia therapy in the postanesthesia care unit: A review. Journal of Post Anesthesia Nursing 5(4): 254–63 MedlineGoogle Scholar
  • Bentley D W, Bradley SF, High K, Schoenbaum S, Taler G, Yoshinkawa TT (2001) Practice guideline for evaluation for fever in infection in long-term care facilities. Journal of the American Geriatric Society 49: 210–22 Crossref, MedlineGoogle Scholar
  • Benzinger M (1969) Tympanic thermometry in anaesthesia and surgery. The JAMA 209(8): 1207–11. Crossref, MedlineGoogle Scholar
  • Betta V, Cascetta F, Sepe D (1997) An assessment of infrared tympanic thermometers for body temperature measurement. Physiol Meas 18(3): 215–25 Crossref, MedlineGoogle Scholar
  • Bland J, Altman D (1999) Measuring agreement in method comparison studies. Statistical Methods in Medical Research 8(2): 135–60. Crossref, MedlineGoogle Scholar
  • Blatties C (1998) ‘Methods of temperature measurement’. In: Physiology and Pathophysiology of Temperature Regulation. Blatties C (ed.) World Scientific Publishing Co. Pte. Ltd, Singapore CrossrefGoogle Scholar
  • Boulant J (1997) ‘Thermoregulation’. In: Fever. Basic Mechanisms and Management. Mackowiak PA (ed.) Lippincott Raven, Philadelphia, New York Google Scholar
  • Boulant J (1998) ‘Neural thermal reception and regulation of body temperature’. In: Physiology and Pathophysiology of Temperature Regulation. Blatties C (ed.) World Scientific Publishing Co. Pte. Ltd, Singapore Google Scholar
  • Brennan D, Falk J, Rothbrock S, Kerr R (1995) Reliability of infrared tympanic thermometry in the detection of rectal fever in children. Ann Emerg Med 25(1): 21–30 Crossref, MedlineGoogle Scholar
  • Bridges E, Thomas K (2009) Noninvasive measurement of body temperature in critically ill patients. Crit Care Nurse 29(3): 94–7 Crossref, MedlineGoogle Scholar
  • Cabanac M (1998) ‘Thermiatrics and behaviour’. In: Physiology and Pathophysiology of Temperature Regulation. Blatties C (ed.) World Scientific Publishing Co. Pte. Ltd, Singapore CrossrefGoogle Scholar
  • Castle SC, Norman DC, Yeh MM, Miller D, Yoshinkawa TT (1991) Fever response in elderly nursing home residents: Are the older truly colder? J Am Geriatr Soc 39(9): 853–7 Crossref, MedlineGoogle Scholar
  • Castle SC, Toledo S, Daskel S, Norman D (1992) The equivalence of infrared tympanic membrane thermometry with standard thermometer in nursing home residents. J Am Geriatr Soc 40(12): 1212–6 Crossref, MedlineGoogle Scholar
  • Chamberlain JM, Grandmer J, Rubinoff JL, Klein BL, Waisman Y, Huey M (1991) Comparison of a tympanic thermometer to rectal thermometer and oral thermometers in a pediatric emergency department. Clin Pediatr (Phila) 30(4 Suppl.): 24–9 Crossref, MedlineGoogle Scholar
  • Chamberlain JM, Torndrup TE, Alexander DT et al. (1995) Determination of normal ear temperature with an infrared emission detection thermometer. Ann Emerg Med 25(1): 15–20 Crossref, MedlineGoogle Scholar
  • Charkouidan N (2003) Skin blood flow in adult human thermoregulation: how it works, when it does not, and why. Mayo Clinic Proceedings http://tinyurl.com/p7hqry9 (accessed 16 July 2013) Google Scholar
  • Childs C, Harrison R, Hodkinson C (1999) Tympanic membrane temperature as a measure of core temperature. Arch Dis Child 80: 262–6 Crossref, MedlineGoogle Scholar
  • Cooper K, Cranston W, Snell E (1964) Temperature in the external auditory meatus as an index of central temperature changes. J Appl Physiol 19: 1032–5 Crossref, MedlineGoogle Scholar
  • Cranston WI, Gerbrandy J, Snell ES (1954) Oral, rectal and oesophageal temperatures and some factors affecting them in man. J Physio 126(2): 347–58 Crossref, MedlineGoogle Scholar
  • Crawford D, Hicks B, Thompdon M (2006) Which thermometer? Factors influencing best choise for intermittent clinical temperature assessment. J Med Eng Technol 30(4): 199–211 Crossref, MedlineGoogle Scholar
  • Cristofaro P (2004) Infections and fever in the elderly. J Am Podiatr Med Assoc 94(2): 126–34 Crossref, MedlineGoogle Scholar
  • Doezema D, Lunt M, Tandberg D (1993) Cerumen occlusion lowers infrared tympanic membrane temperature measurement. Acad Emerg Med 2(1):17–9 CrossrefGoogle Scholar
  • Duberg T, Lundholm C, Holmberg H (2007) Örontermometer inte fullgott alternativ till rektaltermometer (Ear thermometer not satisfactory alternative to rektaltermometer). Läkartidningen (In Swedish) 104: 1479–82 MedlineGoogle Scholar
  • Dubois EF (1951) The many different temperatures of the human body and its parts. West J Surg Obstet Gynecol 59(9): 476–90 MedlineGoogle Scholar
  • Edling L, Carlsson R, Magnusson A, Holmberg H (2010) Temperaturmätning i panna eller axill inte tillförlitlig: Metoder och termometrar jämförda med rektalmätning som referens (Temperature measurement in forehead or axilla not reliable: Methods and thermometers compared with rectal temperature as reference). Läkartidningen In Swedish 46–90, 2888 MedlineGoogle Scholar
  • Emmoth U, Edwinsson-Månsson M (1997) Omvårdnad vid feber. Vård i Norden (In Swedish) 17: 4–8 MedlineGoogle Scholar
  • Erickson R (1980) Oral temperature differences in relation to thermometer and technique. Nurs Res 29(3): 157–64 Crossref, MedlineGoogle Scholar
  • Fallis W (2000) Oral measurement of temperature in orally intubated critical care patients: State-of-the-science review. Am J Crit Care 9(5): 334–43 MedlineGoogle Scholar
  • Fraden J (1991) The development of Thermoscan instant thermometer. Clin Pediatr (Phila) (4 Suppl): 11–2 Crossref, MedlineGoogle Scholar
  • Gerbrandy J, Snell ES, Cranston WI (1954) Oral, rectal and oesophageal temperatures in relation to central temperature control in man. Clin Sci (Lond) 13(4): 615–24 MedlineGoogle Scholar
  • Giuliano K, Scott S, Elliot S, Giuliano A (1999) Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. Crit Care Med 27(10): 2188–93 Crossref, MedlineGoogle Scholar
  • Giuliano K, Giuliano A, Scott S et al. (2000) Temperature measurement in critically ill adults: A comparison of tympanic and oral methods. Am J Crit Care 9(4): 254–61 MedlineGoogle Scholar
  • Grände PO (1992) New haemodynamic aspects on treatment of posttraumatic brain edema. Conference proceedings. Swedish Association of Anesthesia and Intensive Care, 41–6: Lund Google Scholar
  • Guyton A, Hall J (2000) ‘Body temperature, temperature regulation and fever.’ In: Textbook of Medical Physiology. Guyton a C., H. J. (ed.) WB Saunders Company, Philadelphia, Pennsylvania Google Scholar
  • Howell TH (1972) Axillary temperatures in aged women. Age Ageing 1(4): 250–4 Crossref, MedlineGoogle Scholar
  • Holtzclaw KWJ, Person C, Green BD. (1993) Einstein coefficients for emission from high rotational states of the OH(X2π) radical. J Quant Spectrosc. Radiat. Transfer. 49: 223 CrossrefGoogle Scholar
  • Iso (2009) Medical electrical equipment_ Par 2–56: Particular requirements för basic safety and essential performance of clinical thermometers for body temperature measurement. Switzerland. Google Scholar
  • Jakobsson J, Nilsson A, Carlsson L (1992) Core temperature measured in the auricular canal: comparison between four different tympanic thermometers. Acta Anaesthesiol Scand 36(8): 819–24 Crossref, MedlineGoogle Scholar
  • Kistemaker J, Den Hartog E, Daanen H (2006) Reliability of an infrared skin thermometer for core temperature measurements. J Med Eng Technol 30(4): 252–61 Crossref, MedlineGoogle Scholar
  • Lee V, Mckenzie N, Cathcart M (1999) Ear and oral temperatures under usual practice conditions. Research for Nursing Practice 1(1):8 Google Scholar
  • Lefrant J-Y, Muller, L., Emmanuel De La Coussaye (2003) Temperature measurement in intensive care patients: comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method. Intensive Care Med 29(3): 414–8 Crossref, MedlineGoogle Scholar
  • Liu C, Chang R, Chang W (2004) Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome. Infect Control Hosp Epidemiol 25(12): 1109–11 Crossref, MedlineGoogle Scholar
  • Loeb M (2004) Pneumonia in the elderly. Current Opinion in Infectious Diseases, 17(2): 127–30 Crossref, MedlineGoogle Scholar
  • Lu SS, Leasure A Dai Y (2010) A systematic review of body temperature variations in older people. J Clin Nurs 19(1–2): 4–16 CrossrefGoogle Scholar
  • Mackowiak PA, Wassermann SS (1995) Physicians perceptions regarding body temperature in health and disease. South Med J 88(9): 934–8 Crossref, MedlineGoogle Scholar
  • Mackowiak PA (1997a) ‘Clinical thermometric measurements’. In: Fever. Basic Mechanisms and Management.Mackowiak, P. A. (ed.). Lippincott Raven, Philadelphia, New York Google Scholar
  • Mackowiak PA (1997b) ‘History of clinical thermometry’. In: Fever. Basic Mechanisms and management. Mackowiak PA (ed.) Philadelphia, New York: Lippincott Raven Google Scholar
  • Mccarthy P, Heusch A (2006) The vagaries of ear temperature assessment. J Med Eng Technol 30(4): 242–51 Crossref, MedlineGoogle Scholar
  • Mangat J, Standley T, Prevost A, Vasconcelos J, White P. (2010) A comparison of technologies used for estimation of body temperature. Physiol Meas 31(9): 1105–18 Crossref, MedlineGoogle Scholar
  • Modell J, Katholi C, Kumaramangalam S, Hudson E, Graham D (1998) Unreliability of the infrared tympanic thermometer in clinical practice: A comparative study with oral mercury and oral electronic thermometers. South Med J 91(7): 649–54 Crossref, MedlineGoogle Scholar
  • Nielsen B, Kaciuba-Uscilko H (1998) ‘Temperature regulation in exercise’. In: Physiology and pathophysiology of temperature regulation. Blatteis, C. (ed.). World Scientific Publishing Co. Pte. Ltd, Singapore CrossrefGoogle Scholar
  • Norman DC (2000) Fever in the elderly. Clinical Infectious Diseases 31(1): 145–51 CrossrefGoogle Scholar
  • Petersen M, Hauge H (1997) Can training improve the results with infrared tympanic thermometers? Acta Anaesthesiol Scand 41(8): 1066–70 Crossref, MedlineGoogle Scholar
  • Pompei M (1999) Temperature assessment via the temporal artert; Validation of a new method. Arterial heat balance thermometry at an exposed skin site: In: Accuracy, comfort and convenience for patient and clinican. Report, Exergen Corporation, Google Scholar
  • Pursell E, While A, Coomber B (2009) Tympanic thermometry--normal temperature and reliability. Paediatr Nurs 21(6): 40–3 CrossrefGoogle Scholar
  • Rabinowitz RP, Cookson SY, Wasserman SS et al. (1996) Effects of anatomic site, oral stimulation, and body position on estimates of body temperature. Arch Intern Med 156(7): 777–80 Crossref, MedlineGoogle Scholar
  • Robb P, Shahab R (2001) Infrared transtympanic temperature measurement and otitis media with effusion. Int J Pediatr Otorhinolaryngol 59(3): 195–200 Crossref, MedlineGoogle Scholar
  • Robinson J, Charlton J, Seal R. Spady D, Joffres M (1998a) Oesophageal, rectal, xillary, tympanic and pulmonary artery temperatures during cardiac surgery. Can J Anaesth 45(4): 317–23 Crossref, MedlineGoogle Scholar
  • Robinson JL, Seal RF, Spady DW, Joffres MR (1998b) Comparison of oesophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children. J Pediatr 133(4): 553–6 Crossref, MedlineGoogle Scholar
  • Rotello L, Crawford L, Terndrup T (1996) Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures. Crit Care Med 24(9): 1501–6 Crossref, MedlineGoogle Scholar
  • Rumana CS, Gopinath SP, Uzura M, Valadka AB, Robertson CS (1998) Brain temperature exceeds systemic temperature in head-injured patients. Crit Care Med 26(3): 562–7 Crossref, MedlineGoogle Scholar
  • Sato K, Kane N, Soos G, Gisolfi C, Kondo N, Sato K (1996) Reexamination of tympanic membrane temperature as a core temperature. J Appl Physio 80(4): 1233–9 Crossref, MedlineGoogle Scholar
  • Shibasaki M, Kondo N, Tominaga H et al. (1998) Continuous measurement of tympanic temperature with a new infrared method using an optical fiber. J Appl Physiol 85(3): 921–6 Crossref, MedlineGoogle Scholar
  • Shinozaki T, Sugimoto H, Taneda M et al. (1993) Effect of mild hypothermia on uncontrollable intracranial hypertension after severe head injury. J Neurosurg 79(3): 363–8 Crossref, MedlineGoogle Scholar
  • Smitz S, Giagoultsis T, Dewé W, Albert A (2000) Comparison of rectal and infrared ear temperatures in older hospital inpatients.J Am Geriatr Soc 48(1): 63–6 Crossref, MedlineGoogle Scholar
  • Stavem K, Saxholm H, Smith-Erichsen N (1997) Accuracy of infrared ear thermometry in adult patients. Intensive Care Med 23(1): 100–5 Crossref, MedlineGoogle Scholar
  • Stephenson LA (1997) ‘Circadian timekeeping’. In: Fever. Basic Mechanisms and Management. Mackowiak, P. A. (ed.). Lippincott Raven, Philadelphia, New York Google Scholar
  • Suleman M, Doufas A, Akca O. Ducharme M, Di S (2002) Unsufficiency in a new temporal-artery thermometer for adult and pediatric patients. Anesth Analg 95(1): 67–71 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Wahren LK, Hamrin E (1998) Nursing care in fever: Assessment and implementation. Vård i Norden 18: 27–30 Google Scholar
  • Sund-Levander M, Wahren LK (2000) Assessment and prevention of shivering in patients with severe cerebral injury. A pilot study. J Clin Nurs 9(1): 55–61 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Wahren LK (2002) The impact of ADL-status, dementia and body mass index on normal body temperature in elderly nursing home residents. Arch Gerontol Geriat 35(2): 161–9 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Örtqvist Å, Grodzinsky E, Klefsgård Ö, Wahren LK (2003) Morbidity, mortality and clinical presentation of nursing home-acquired pneumonia in a Swedish population. Scand J Infect Dis 35(5): 306–10 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Grodzinsky E, Loyd D, Wahren LK (2004) Error in body temperature assessment related to individual variation, measuring technique and equipment. Int J Nurs Pract 10(5): 216–23 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Grodzinsky E (2009) Time for a change to assess and evaluate body temperature in clinical practice. IInt J Nurs Pract 15(4): 241–9 Crossref, MedlineGoogle Scholar
  • Sund-Levander M, Grodzinsky E (2012). Accuracy when assessing and evaluating body temperature in clinical practice: Time for a change. Thermology International 22: 25–32 Google Scholar
  • Terndrup T, Allegra, J, Kealy J (1989) A comparison of oral, rectal, and tympanic membrane-derived temperature changes after ingestion of liquids and smoking. Am J Emerg Med 7(2): 150–4 Crossref, MedlineGoogle Scholar
  • Tingström P, Milberg A, Sund-Levander M (2010) Early nonspecific signs and symptoms of infection in institutionalized elderly persons: perceptions of nursing assistants. Scand J Caring Sc 24(1): 24–31 Crossref, MedlineGoogle Scholar
  • Tochihara Y (2000) ‘Thermal comfort and blood pressure changes in the elderly’. In: Proceedings of the IX Conference on Environmental Ergonomics, 2000 Dortmund 243–247 Werner JHexamer M (eds) Google Scholar
  • Togawa T (1985) Body temperature measurement. Clinical Physiological Measurement. 6: 83–102 Crossref, MedlineGoogle Scholar
  • Van Someren E, Raymann R, Scherder E, Daanen H, Swaab D (2002) Circadian and age-related modulation of thermoreception and temperature regulation: mechanisms and functional implications. Ageing Res Rev 1(4): 721–78 Crossref, MedlineGoogle Scholar
  • Varney S, Manthey D, Culpepper V, Creedon J (2001) A comparison of oral, tympanic, and rectal temperature measurement in the elderly. J Emerg Med 22(2): 153–7 CrossrefGoogle Scholar
  • Werner J (1998) Biophysics of heat exchange between body and environment. In: Physiology and Pathophysiology of Temperature Regulation. Blatteis C (ed.) World Scientific Publishing Co. Pte. Ltd, Singapore CrossrefGoogle Scholar
  • Wunderlich CA, Reeve JC (1869) The course of the temperature in diseases: a guide to clinical thermometry. Am J Med Sci 57: 423–47. Google Scholar
  • Zehner WJ,. Terndrup TE (1991) The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures. Clin Pediatr (Phila) 30(4 Suppl): 61–4 Crossref, MedlineGoogle Scholar

This website is intended for healthcare professionals